Copyright © 2015 杭州华三通信技术有限公司 版权所有,保留一切权利。
非经本公司书面许可,任何单位和个人不得擅自摘抄、复制本文档内容的部分或全部,并不得以任何形式传播。本文档中的信息可能变动,恕不另行通知。
目 录
1 简介 ······················································································································································ 1 2 配置前提 ··············································································································································· 1 3 SNMPv1/SNMPv2c配置举例 ················································································································ 1
3.1 组网需求 ··············································································································································· 1 3.2 使用版本 ··············································································································································· 1 3.3 配置注意事项 ········································································································································ 1 3.4 配置步骤 ··············································································································································· 2
3.4.1 设备的配置 ································································································································· 2 3.4.2 NMS的配置 ································································································································ 2 3.5 验证配置 ··············································································································································· 3 3.6 配置文件 ··············································································································································· 5
4 SNMPv3配置举例 ································································································································ 5
4.1 组网需求 ··············································································································································· 5 4.2 使用版本 ··············································································································································· 5 4.3 配置注意事项 ········································································································································ 5 4.4 配置步骤 ··············································································································································· 6
4.4.1 设备的配置 ································································································································· 6 4.4.2 NMS的配置 ································································································································ 6 4.4.3 验证配置 ···································································································································· 8 4.5 配置文件 ············································································································································· 10
5 相关资料 ············································································································································· 10
i
1 简介
本文档介绍了SNMP功能典型配置举例。
2 配置前提
本文档不严格与具体软、硬件版本对应,如果使用过程中与产品实际情况有差异,请参考相关产品手册,或以设备实际情况为准。
本文档中的配置均是在实验室环境下进行的配置和验证,配置前设备的所有参数均采用出厂时的缺省配置。如果您已经对设备进行了配置,为了保证配置效果,请确认现有配置和以下举例中的配置不冲突。
本文档假设您已了解SNMP特性。
3 SNMPv1/SNMPv2c配置举例
3.1 组网需求
如图1所示,服务器作为NMS通过SNMPv1/SNMPv2c协议对设备进行配置文件备份,并且当设备出现故障时能够主动向NMS发送告警信息。 图1 SNMPv1/v2c功能典型配置组网图
3.2 使用版本
本举例是在S5820V2_5830V2-CMW710-R2418P01版本上进行配置和验证的。
3.3 配置注意事项
• • •
SNMPv2c与SNMPv1配置方法完全一致,本举例中以配置SNMPv2c为例进行介绍。 用户在设备和NMS上配置的SNMP版本号和团体字必须一致,否则,NMS无法对设备进行管理和维护。
不同厂商的NMS软件配置方法不同,本配置举例中,以IMC PLAT 7.0 (E0202)为例进行介绍。
1
3.4 配置步骤
3.4.1 设备的配置
# 设置Agent使用的SNMP版本为v2c、只读团体名为readtest,读写团体名为writetest。
[Agent] snmp-agent sys-info version v2c [Agent] snmp-agent community read readtest [Agent] snmp-agent community write writetest # 设置设备的联系人和位置信息,以方便维护。 [Agent] snmp-agent sys-info contact Mr.Wang-Tel:3306 [Agent] snmp-agent sys-info location telephone-closet,3rd-floor # 设置允许向NMS发送告警信息,使用的团体名为traptest。 [Agent] snmp-agent trap enable [Agent] snmp-agent target-host trap address udp-domain 192.168.100.4 params securityname traptest 3.4.2 NMS的配置 # 增加设备 登录进入IMC管理平台,选择“资源”页签,单击导航树中的[增加设备]菜单项,进入增加设备配置页面。 • • 设置设备的主机名或IP地址为“192.168.100.68”; 其它参数采用缺省值。 图2 增加设备配置页面 2 # 在该页面中单击“配置SNMP参数”按钮,展开配置SNMP参数页面,单击“设置”,在弹出的对话框中设置如下内容。 • • • • 设置参数类型为“SNMPv2c”; 设置只读团体字为“readtest”; 设置读写团体字为“writetest”; 其它参数采用缺省值,并单击<确定>按钮完成操作。 图3 SNMP参数设置页面 # 在“增加设备”页面单击<确定>按钮,iMC返回增加设备成功信息。 图4 增加设备成功页面 # 增加设备成功后,用户即可通过iMC(NMS)对设备进行配置、管理和维护。不同NMS管理软件配置不同,关于NMS的详细配置,具体请参考NMS的相关手册。 3.5 验证配置 (1) Agent向NMS发送Trap信息 # 完成以上配置之后,在设备上的某个空闲接口执行shutdown或undo shutdown操作,设备会向NMS发送接口状态改变的Trap。 # 在“告警>告警浏览>全部告警”页面中可以查看上述Trap信息。 3 图5 全部告警视图页面 (2) 在NMS上备份Agent配置文件 # 在“资源>设备视图”页签点击“Agent”,进入如图6页面,点击右侧的“备份配置文件”。 图6 备份配置文件 # 操作成功后会显示如下页面。 图7 备份配置文件成功 4 3.6 配置文件 # snmp-agent snmp-agent community write writetest snmp-agent community read readtest snmp-agent sys-info contact Mr.Wang-Tel:3306 snmp-agent sys-info location telephone-closet,3rd-floor snmp-agent sys-info version v2c v3 snmp-agent trap enable arp snmp-agent target-host trap address udp-domain 192.168.100.4 params securityname traptest # 4 SNMPv3配置举例 4.1 组网需求 如图8所示,服务器作为NMS通过SNMPv3协议对设备进行配置文件备份,提供更高的安全性,并且当设备出现故障时能够主动向NMS发送告警信息。 图8 SNMPv3功能典型配置组网图 4.2 使用版本 本举例是在S5820V2_5830V2-CMW710-R2418P01版本上进行配置和验证的。 4.3 配置注意事项 • • • • 用户需要分别对设备和NMS配置SNMP功能,设备与NMS的SNMP配置必须一致,否则,NMS无法对设备进行管理和维护。 不同厂商的NMS软件配置方法不同,本配置举例中,以IMC PLAT 7.0 (E0202)为例进行介绍。 SNMPv3接收Trap报文的目的主机的安全参数要使用设备已配置的v3用户,且安全模型要一致。 SNMPv3的认证密码和加密密码以密文形式保存在配置文件中,密文密码由明文密码和本设备的引擎ID计算后生成。如果要将两台设备的认证密码和加密密码配置为相同值,建议使用明文密码在两台设备上分别手工配置,不要直接拷贝配置文件中的相关配置。因为两台设备的引擎ID不同,会导致密文密码相同,而对应的明文密码不同。 5 4.4 配置步骤 4.4.1 设备的配置 # 设置Agent使用的SNMP版本为v3。 [Agent] snmp-agent sys-info version v3 # 创建MIB视图,名字为mibtest,包含internet子树(OID为“1.3.6.1”)所有对象。 [Agent] snmp-agent mib-view included mibtest 1.3.6.1 # 创建SNMPv3组managev3group,并配置与该组绑定的SNMPv3用户与NMS建立连接时,均进行认证和加密,NMS可以对设备进行读写的视图均为mibtest。 [Agent] snmp-agent group v3 managev3group privacy read-view mibtest write-view mibtest notify-view mibtest # 设置SNMPv3用户名为managev3user,认证算法为SHA-1,明文认证密码为123456TESTauth&!,加密算法为AES,明文加密密码是123456TESTencr&!。 [Agent] snmp-agent usm-user v3 managev3user managev3group simple authentication-mode sha 123456TESTauth&! privacy-mode aes128 123456TESTencr&! # 开启SNMP告警功能。 [Agent] snmp-agent trap enable # 设置接收SNMP告警信息的目的主机IP地址,即NMS的IP地址,配置安全认证参数为managev3user。 [Agent] snmp-agent target-host trap address udp-domain 192.168.100.4 params securityname managev3user v3 privacy 4.4.2 NMS的配置 # 登录iMC,选择“系统管理”页签,单击导航树中的[资源管理/SNMP模板]菜单项,进入SNMP模板配置页面,在该页面中单击<增加>按钮,进入增加SNMP模板配置页面。 • • • • • • 配置SNMP模板的名称为SNMPv3。 选择参数类型为SNMPv3 Priv-Aes128 Auth-Sha。 配置SNMP用户名为managev3user。 明文认证密码为123456TESTauth&!。 明文加密密码为123456TESTencr&!。 其它参数采用缺省值,并单击<确定>按钮完成操作。 6 图9 增加SNMP模板页面 # 选择“资源”页签,单击导航树中的[资源管理/增加设备]菜单项,进入增加设备配置页面,在该页面中输入设备的主机名或IP地址,并点击<配置SNMP参数/设置>链接。 图10 增加设备页面 # 进入SNMP参数设置页面配置SNMP参数 • • 选择“从已有的SNMP参数模板中选取”。 选择名称为“SNMPv3”的SNMP模板。 7 • 单击<确定>按钮完成操作,返回到“增加设备”页面。 图11 SNMP参数设置页面 # 在“增加设备”页面单击<确定>按钮,iMC返回增加设备成功信息。 图12 增加设备成功页面 # 增加设备成功后,用户即可通过iMC(NMS)对设备进行配置、管理和维护。不同NMS管理软件配置不同,关于NMS的详细配置,具体请参考NMS的相关手册。 4.4.3 验证配置 (1) Agent向NMS发送Trap信息 # 完成以上配置之后,在设备上的某个空闲接口执行shutdown或undo shutdown操作,设备会向NMS发送接口状态改变的Trap。 # 在“告警>告警浏览>全部告警”页面中可以查看上述Trap信息。 8 图13 全部告警视图页面 (2) 在NMS上备份Agent配置文件 # 在“资源>设备视图”页签点击“Agent”,进入如下页面,点击右侧的“备份配置文件”。 图14 备份配置文件 # 操作成功后会显示如下页面。 图15 备份配置文件成功 9 4.5 配置文件 # snmp-agent sys-info version v3 snmp-agent group v3 managev3group privacy read-view mibtest write-view mibtest notify-view mibtest snmp-agent mib-view included mibtest internet snmp-agent trap enable arp snmp-agent target-host trap address udp-domain 192.168.100.4 params securityname managev3user v3 privacy snmp-agent usm-user v3 managev3user managev3group cipher authentication-mode sha $c$3$5JaJZ6gNXlyNRq2FR2ELDT3QQH1exwJRWdYYq7eLfcBewuM5ncM= privacy-mode aes128 $c$3$+bbXZS4+PnsLDyr16OogzBckaLzR6XMDwZQuLBU8RM+dpw== # 5 相关资料 • • H3C S5830V2[S5820V2]系列以太网交换机 网络管理和监控配置指导-Release 24xx系列 H3C S5830V2[S5820V2]系列以太网交换机 网络管理和监控命令参考-Release 24xx系列 10
因篇幅问题不能全部显示,请点此查看更多更全内容