MOS FET RelaysSmallest Class in market, USOP Package MOS FET Relays (COFF (typical): 20 pF, RON (typical): 1 Ω) with Low Output Capacitance and ON Resistance (C × R = 20 pF•Ω) in a 60-V Load Voltage Model.•ON resistance of 1 Ω (typical) suppresses output signal attenuation.RoHS compliant
Note:
G3VM-61PRThe actual product is marked differently from the imageshown here.
■Application Examples
•Semiconductor inspection tools•Measurement devices•Broadband systems•Data loggers
■List of Models (Ask your OMRON representative for delivery times.)
Contact formSPST-NONote:
TerminalsSurface-mounting terminals
Load voltage (peak value)
(See note)60 V
ModelG3VM-61PRG3VM-61PR(TR)
Minimum packaging unit
Number per tape---1,500
1.Ask your OMRON representative for orders under 1,500 pcs.2.Tape-cut USOPs are packaged without humidity resistance.
Use manual soldering to mount them. Refer to common precautions.3.The AC peak and DC value is given for the load voltages.
■Dimensions
Note:
All units are in millimeters unless otherwise indicated.
G3VM-61PR
3.252.050.151.65(0.4)Note:A tolerance of ±0.2 mm applies
to all dimensions unless other-wise specified.Weight: 0.03 gNote:The actual product is marked differently
from the image shown here.
1.272.22.85(0.35)0.2■Terminal Arrangement/Internal Connections (Top View)
G3VM-61PR
431Pin 12Pin 1The actual product is marked differently from the image shown here.Beveled side is input side.■Actual Mounting Pad Dimensions (Recommended Value, Top View)
G3VM-61PR
0.852.90.81.27http://oneic.com/
G3VM-61PR
■Absolute Maximum Ratings (Ta = 25°C)
Item
Input
LED forward current
LED forward current reduction rateLED reverse voltageConnection temperature
Output
Load voltage (AC peak / DC)
Continuous load current (AC peak / DC)ON current reduction rateConnection temperature
Dielectric strength between input and output (See note 1.)
Ambient operating temperatureStorage temperatureSoldering temperature
IF∆ IF/°CVRTjVOFFIO∆ IO/°CTjVI-OTaTstg---Symbol
50−0.5512560400−4.0125500−40 to +85−40 to +125260
Rating
mAmA/°CV°CVmAmA/°C°CVrms°C°C°C
AC for 1 min
With no icing or condensationWith no icing or condensation
10s
Ta ≥ 25°CTa ≥ 25°C
Unit
Measurement Conditions
G3VM-61PR
Note:
1.The dielectric strength be-tween the input and out-put was checked by
applying voltage between all pins as a group on the LED side and all pins as a group on the light-receiv-ing side.
■Electrical Characteristics (Ta = 25°C)
Item
Input
LED forward voltageReverse current
Capacity between terminalsTrigger LED forward current
Output
Maximum resistance with output ONCurrent leakage when the relay is openCapacity between terminals
Capacity between I/O terminals
Insulation resistance between I/O terminalsTurn-ON timeTurn-OFF time
SymbolVFIRCTIFTRONILEAKCOFFCI-ORI-OtONtOFF
Mini-mum1.0---------------------1,000------Typical1.15---150.51.0---200.3---0.30.3
Maxi-mum1.310---31.5130------0.50.5
VµApFmAΩnApFpFMΩmsmsUnit
Measurement conditionsIF = 10 mAVR = 5 VV = 0, f = 1 MHzIO = 100 mA
IF = 5 mA, IO = 400 mA, t < 1 s
VOFF = 60 V, Ta = 25°CV = 0, f = 1 MHz, t < 1 s
f = 1 MHz, Vs = 0 VVI-O = 500 VDC, RoH ≤ 60%
IF = 5 mA, RL = 200 Ω, VDD = 20 V (See note 2.)
VOUTIFNote:
2.Turn-ON and Turn-OFF
Times
IF1243RLVDDVOUT10%tON90%tOFF■Recommended Operating Conditions
Use the G3VM under the following conditions so that the Relay will operate properly.
Item
Load voltage (AC peak / DC)Operating LED forward current
Continuous load current (AC peak / DC)Operating temperature
IFIOTa
SymbolVDD
5---−20Minimum------7.5------Typical
Maximum482040065
VmAmA°C
Unit
■Engineering Data
Load Current vs. Ambient Temperature
G3VM-61PR
Load current (mA)500■Safety Precautions
Refer to “Common Precautions” for all G3VM models.
4003002001000−20020406080100Ambient temperature (°C)http://oneic.com/
分销商库存信息:
OMRON
G3VM-61PR(TR)
G3VM-61PR